PRODUCT RANGE

MICROBLUE

MAXIBLUE

MEGABLUE

ARCTIKBLUE

SENSING OPTIONS

ACCESSORIES

© BLUEDIAMOND™ 2019

DISTRIBUTED BY:

Asset-2-compressor (6).png

REFRIGERATION PUMP RANGE

BLUEDIAMOND has designed, tested and developed its refrigeration pump range to cover a multitude of applications and scenarios. Utilising our established and highly reliable ARCTIKBLUE, the BLUEDIAMOND refrigeration range now has two new additions that have taken the advancements made by the ARCTIKBLUE and reduced the in size, giving you the POLARBLUE and ARCTIKBLUE SLIM.

Download a copy of our brochure here for more information

*SMALL FREE STANDING FRIDGES

*SMALLEST UNIT ON THE MARKET

ARCTIK-SLIM-compressor.png

*LARGE INDUSTRIAL FRIDGES

Asset-15-compressor (1).jpg
ARCTIKBLUE-compressor.png

THERMISTOR SENSOR (ENERGY EFFICIENT)

The presence of condensate trips the hi-low solid state level sensors to switch the pump on/off. This means that the pump is run only when condensate is produced and the alarm shuts off the unit in the case of a fault, restarting when clear. The slim filter probe, which houses the water sensors and high level alarm has no moving parts to become clogged or stuck making it an ideal alternative to existing float switches.

FILTRATION

Protecting the sensors is our swap out guard, the filter element can be changed over as a complete assembly during preventative maintenance service schedules. The main tray is also protected against objects larger than Ø2.5mm allowing the pump to remove condensate, sludge and debris. 

PITCHED

All of the refrigeration trays have been tilted on a 10 ° angle. This ensures that the condensate that has been produced by the fridges can be gravity fed into the pump inlet. This also helps to push and debris through the filtration guard without having to use vacuum devices to push it through.

ENERGY EFFICIENT

Evaporating the condensate in a store environment adds unnecessary cost and additional energy wastage due to the need for complicated dehumidification systems. On top of this, stores fitted with air conditioning systems will waste further energy due to the heating factor of an evaporation pan.

BETTER HYGIENE

Sludge and slime build up in refrigeration units is a common and consistent problem. What others see as an after-market fix (cleaning products & chemicals) we see as an unnecessary but expensive maintenance cost. Evaporator pans will burn an unsavoury cocktail into the store atmosphere, aerating a mixture of chemicals and bacteria near food and customers.

FIXED DRAINAGE

PUMP INSTALL

STORE VERSATILITY

The digging of drains will lock a store to its designed configuration. If a store desires to alter its layout in the future, extensive work must be completed, not only to re-dig drains but to fill in existing obsolete ones. When this old fashioned method is replaced with an ARCTIKBLUE, store layout becomes much more versatile, allowing total freedom to reposition cabinets for ergonomic or promotional cause. The use of an ARCTIKBLUE also opens up the opportunity to retrofit stores with little effort or expense, ensuring stores are totally future-proofed.

PUMPS AIR GAS & LIQUID

CAN PUMP SLUDGE & SLIME

A common problem with refrigeration units is the build-up of slime and sludge. What others see as a problem that can be solved by aftermarket cleaning products, our patented design can simply pump and remove that from the system without premature failure.